Setting CCMS Monitor Status Thresholds

SiteScope Application Monitors allow you to set multiple threshold conditions to determine the status reported by each monitor. The individual conditions are combined as logical OR relationships so that when one or more of the conditions (for example any of the conditions for Error if) are met the monitor status is set to the applicable condition. If multiple conditions are met for more than one status condition (such as conditions for both error and for warning), the status for the monitor is set to the highest valued condition. Thus a match of an error condition and a warning condition would be reported as an error status, error being the highest value, warning the next highest and good the lowest value.


Error if
Use one or more of the selection boxes in this item to define one or more error conditions for this monitor. Use the drop-down lists in these items to change error threshold(s) relative to the counters have selected to check with this monitor. After choosing a counter or parameter, use the comparison operator drop-down list to specify an error threshold such as: >= (greater than or equal to), != (not equal to), or < (less than) and enter a comparison value in the box provided. Comparison values should be entered as whole numbers.


Warning if
Use one or more of the selection boxes in this item to define one or more warning conditions for this monitor. Use the drop-down lists in these items to change warning threshold(s) relative to the counters you have selected to check with this monitor. Set these values relative to those you set for the error threshold in the Error if item.


Good if
You can set this monitor to return a good status for certain conditions. You may define those conditions here. Complete this item as you would for the Error if and Warning if items.